Group A2 Lodging Houses &
                                                     50                     75
                      Special residential

                      Group F Mercantile
                                                     50                     75
                      (Commercial)


                                   Table 5: In terms of Fire escape (Source: NBC 2016, KMBR 2023)

                                                                   No. of Occupants per unit exit
                        Thesis Report V-SPARC VIT

                      Units

                                                                   width of Stairway
                      50cm Width                                   1 Unit
                      25cm Width                                   1/2 unit
                      Less than 25 CM                              No unit



                                    Table 6: In terms of Electricity(Source: NBC 2016, KMBR 2023)

                      Low Medium Voltage (Distance to be

                      implemented for the building)

                      Vertical - 2.5m                              Horizontal - 1.2m



                               Table 7: In terms of Rainwater Harvesting(Source: NBC 2016, KMBR 2023)

                                                                          ac

                                                                       p
                                                                   C
                                                                     a

                      Wells/Rainwater Harvestingity of Water Tank
                                                                   Residential/Commercial 25 l/sq.m

                      Minimum distance from other boundaries (1.2m)
                                                                   of Covered area

                      No Leech Pit, Sock Pit, Refuse Pit,
                      Earth closet, Septic Tank are not allowed within
                                                                       e
                                                                     s

                                                                            C
                      7.5 m radius of existing well onsumption:135 lphd
                                                                          r
                                                                   U

                                 Table 8: In terms of Wastage System (Source: NBC 2016, KMBR 2023)


                      Wastage systems
                      For every Building with Built area of 100 sq.m Waste disposal or connected to
                      Sewage lines.
                      For every Building with
                      Built area of 300 sq.m Biogas plant
                      Leech pit, sock pit, refuse pit or septic tank shall have a minimum distance of 1.20
                      metres

                      For every 1 person 0.6 kg waste is assumed to be produced