Group A2 Lodging Houses &
50 75
Special residential
Group F Mercantile
50 75
(Commercial)
Table 5: In terms of Fire escape (Source: NBC 2016, KMBR 2023)
No. of Occupants per unit exit
Thesis Report V-SPARC VIT
Units
width of Stairway
50cm Width 1 Unit
25cm Width 1/2 unit
Less than 25 CM No unit
Table 6: In terms of Electricity(Source: NBC 2016, KMBR 2023)
Low Medium Voltage (Distance to be
implemented for the building)
Vertical - 2.5m Horizontal - 1.2m
Table 7: In terms of Rainwater Harvesting(Source: NBC 2016, KMBR 2023)
ac
p
C
a
Wells/Rainwater Harvestingity of Water Tank
Residential/Commercial 25 l/sq.m
Minimum distance from other boundaries (1.2m)
of Covered area
No Leech Pit, Sock Pit, Refuse Pit,
Earth closet, Septic Tank are not allowed within
e
s
C
7.5 m radius of existing well onsumption:135 lphd
r
U
Table 8: In terms of Wastage System (Source: NBC 2016, KMBR 2023)
Wastage systems
For every Building with Built area of 100 sq.m Waste disposal or connected to
Sewage lines.
For every Building with
Built area of 300 sq.m Biogas plant
Leech pit, sock pit, refuse pit or septic tank shall have a minimum distance of 1.20
metres
For every 1 person 0.6 kg waste is assumed to be produced