2.2.14. Sanitation
2.2.14.1. Urinals
• A urinal should not be set closer than 450mm
from its center to any side wall partition, vanity,
Thesis Report V-SPARC VIT
or other obstruction, or closer than 900mm
center-to-center between adjacent fixtures.
• There should be at least 900mm of clearance in
front of the urinal to any wall, fixture, or door.
• Individual wall-hung urinal units shall be at
least 300mm wide, and the lip of the collection
area shall project from the wall by at least
300mm.
• To provide a visual barrier between urinals,
modesty boards of at least 300 mm by 1800 mm
(Height) should be placed between them.
Figure 2 Sanitary requirement in public building
2.2.14.2. Wash Basins
Wash basins should be substantial in size.
The basins should have a minimum size of 500mm in length and 400mm in width
2.2.14.3. Water Closets:
• A WC should not be set closer than 450mm from its centre to any side wall,
partition, vanity or other obstruction.
• There should be at least a 900mm clearance in front of the WC to any wall, fixture or door.
• Supply a predetermined quantity of not more than 4.5 litres of water per flush after each
use.