2.2.15. Ventilation
2.2.15.1. Mechanical Ventilation
Where mechanical means are used for ventilation, there should be cross ventilation
and the air exchange rate should have a minimum of 15 air changes per hour.
Thesis Report V-SPARC VIT
The exhaust air should be discharged to the exterior of the building at a position at
least 2 m above the pavement level and at least 5 m from any window or fresh air intake.
2.2.15.2. Natural Ventilation
• Appropriate fresh air intake grilles must be installed for natural ventilation in order to
guarantee five air changes per hour.
• Some nice toilet materials include:
• Floor: Terrazzo, uniform tiles, natural stone, and non-slip ceramic tiles.
• Wall: Glass block, aluminum panels, phenolic cladding, stainless steel, enameled steel
panels, ceramic tiles, natural stone, and homogenous tiles.
• Ceiling: Mineral fiberboard, plaster board with fibers, aluminum strips or panels
2.2.16. MULTILEVEL PARKING STANDARDS
PARKING REQUIREMENTS
Spaces Standards
(i)Floor area upto 50square metres -Nil
(a )Shop (ii )Floor area above 50square metre but
exceeding 100square metres -1car space .
(b)Office and firm
(including public and One car space for every 100square metres of floor area.
Semi public offices )
Restaurants One car space for every 100sq.m of floor area
Cinema halls One space for every 20sq.m of auditorium area
11