2.2.17. BASEMENT FLOOR
(a) The height of basement floor shall not exceed 1.2 meters above ground level and the
headroom shall be minimum 2.4 meters.
(b) In cases where second basement is proposed for parking and incidental uses,
sufficient provision for lighting and ventilation shall be made.
Thesis Report V-SPARC VIT
(c). A stand-by electric generator of adequate capacity for running lift and water pump,
and a room to accommodate the generator.
(d). An electrical room of not less than 6m x 4m in area with a minimum head room of
2.75 meters to accommodate electric transformer in the ground floor.
(e). At least one-meter room of size 2.4m x 2.4m for every 10 consumers or 3 floors
whichever is less. The meter room shall be provided in the ground floor.
2.2.18. SETBACK
2.2.18.1. Structures that can be built on setback
• Motor room of area not exceeding 2 sq.m. each and height not exceeding 1.8m,
without affecting parking and driveway requirements.
• Gate pillars, gopurams, and incidental structures (with height not exceeding 4m) such
as servant room, cloak room, and watch man booth, cycle stand, and toilets.
• Access steps to Ground floor and ramps, closed Well, Water and Sewage Treatment
Plant, Generator, Box type transformers are permitted in the setback area subject to
availability of minimum driveway of 3.00 mts. and parking requirements as per the
approved plan.