Page 30 - 19BAR0037
P. 30

2.1.4.4. Structural System

                            Both the Exhibition and Convention halls are made of steel structural

                     systems. I sections as columns, and further I sections as connecting beams are
                     used to span the 44m lengths, without and central structural supports, as seen

                     in Figure 13. This makes the halls flexible in terms of openness and use. Cross-
                        Thesis Report V-SPARC VIT
                     bracing systems are used to handle wind loads and increase the structural

                     strength of the halls.






























                     Figure 13: I Sections Used as Structural System in the Exhibition Halls



                     2.1.4.5. Air-conditioning System


                            Both  the  Exhibition  and  Convention  halls  are  serviced  with  air-

                     handling-unit (AHU) with air-cooled chiller systems. The chiller systems are

                     accommodated  on  the  roofs  of  the  structures  immediately  above.  These
                     connect to AHU’s. within the structures, which thereafter carry cool air into

                     the halls through ducted systems. Even in the convention hall, AHU units are

                     located at the first floor, easily accessible through stairs for servicing.