Page 10 - 19BAR0015
P. 10

Thesis Report V-SPARC VIT
                          Figure 1 - Typology Classification, Source - Abu Dhabi International Building Code 2013

                  3.3. Construction Types and Material Specifications

                  Construction Types IA and IB: According to the Abu Dhabi International Building Code
                  (Department of Municipal Affairs and Transport, 2013), The museum will adhere to the
                  construction specifications of Type IA, providing flexibility in design with unlimited story
                  heights and floor area, which is essential for creating expansive, uninterrupted gallery
                  spaces. This construction type supports the museum's architectural vision, allowing for a
                  grand scale that enhances visitor immersion within the exhibits.


                  Fire-Resistance and Material Safety: According to the building code, the museum must
                  utilize Class A materials for interior wall and ceiling finishes to ensure the highest level of
                  fire safety. Class A materials have a flame spread index of 0-25, making them highly
                  resistant to fire, which is crucial for protecting both the valuable artifacts housed within the
                  museum and the visitors.

















                     Figure 2 - Fire Resistance Rating Requirements, Source - Abu Dhabi International Building Code 2013



                  3.4. Compliance with Fire-Resistance Requirements


                  Detailed Compliance: The primary structural frame of the museum will include materials
                  that meet a fire-resistance rating of three hours (Type IA), ensuring structural integrity
                  during emergencies. Non-load bearing walls and partitions will also adhere to required
                  fire-resistance standards, enhancing the overall safety of the building.
   5   6   7   8   9   10   11   12   13   14   15