          INFERENCE

          Site has an access potential from Perumbakkam main road and service road.
          Since the site is close to IT office and other industries, it has a potential to draw the working people.
           Since the site has approach from Perumbakkam  road, there, is a scope of having commercial
          buildings along road to draw people.
          Location of site is within 10 min walking distance to residential area.
          Public transportation linking site to many places around the site.
          site is strategically located within walking distance from commercial and residential zone.

                      Thesis Report V-SPARC VIT
          SWOT ANALYSIS


                                                                 WEAKNESS

           STRENGTH                                              - Poor pedestrian way.
           - The presence of a huge green area on and            - The site isn't isolated from the busy main
                                                                 road.
           around the site.
           -Accessible from the main road welcoming              - Lack of shaded walkway around the site.
           expression.                                           -Traffic is relatively busy and congested on
           - The site is near to most of the facilities.         the end of the working hours
                                                                 -the project site is loated at distance 20km
                                                                 from airport





           OPPORTUNITIES
           -Easy accessibility to Perumbakkam,
           Karappakam, Medavakkam, Pallikaranai,
           Semmancheri and Navalur,which had good                                   THREAT
           residential catchment.                                   High vechicular traffice surrounding site.

           -As well as industries & institutions nearby,
           which makes people working/studying to
           come and reside in the project.

          7. DESIGN REQUIREMENT

          7.1. RULES AS PER DTCP APPLICABLE FOR THE SITE:

           S.NO    DESCRIPTION                                    ALL AREA
           1       Minimum road width                             15
           2       Normal permissible FSI                         2.5
           3       Maximum coverage                               50%
           4       Minimum set back                               7m
           5       Space between the block                        7m (for every increase in 6m for building
                                                                  about 30m-addition 1m to be left)

           Dwelling with Unit                                               Number Spaces of Parking

           Floor area upto 50 sq.m                                          Nil

                                                                                                               37