5.2. FTamil Nadu municipalities hill station, building rules, 1993



            SI NO  Description           Continuous building area

                                         if the Project is more than 12 lakhs
            1       Brief statment       Construction should not affect scenic beauty
                                         Prove architectural and esthetic harmony with ecology
            2       Steep                Less tham 1:3 (Height:width) not building constructions
                                         Stability of the soil verified by engineers
            3       Soil
                                         Made up soil within the site should not be used for construction
                                         Permit only if suitable to avoid flooding
            4       Storm water          (Storm water course)
                                         Or raise land to avoid flooding
                                         Clearence of aerial lines
                                         If accessible- horizontally- LT- 1.5m, HT-1.75m
            5       Location             If not accessible- horizontally- 1.25m
                                         If accessible- vertically- 2.5m
                                         If not accesible- vertically- 1.25m

                                         site to be away by
                      Thesis Report V-SPARC VIT
                                         200m away from park
                                         100m away from park

                                         Street width more than 6m
                                         l less than 10m ,width- 1m
            6       Access
                                         l 10-30m, width- 1.5m
                                         steep 1:10 (Height: width)
                    Location of the
            7                            15m away from tank, reservoires, ponds,etc. Prevent contamination
                    building
                                         150m away from reserved forest and wood lands

                                         Stability check- combined dead and superimposed load transfer to
                                         subsoil
            8       Foundation           Depth, immunity damage
                                         Pile foundation- Loose and high depth if building more than 10m in
                                         length.
            9       Plinth               Avoid effectual damage- 4.5m and above
                                         Stability of the soil verified by engineers
            10      Superstructure
                                         Made up soil within the site should not be used for construction
                                                        Table 5.2