6.3.  Cafeteria

               Spaces  required  include  utility  and  storage,

               kitchen,  dining  space  in  the  ratio  of  1:3:6

               respectively, additional spaces include handwash
               and toilets.

                                                                    Fig 60. Functional scheme of small cafeteria

                      Thesis Report V-SPARC VIT
               Dining Area:
               A minimum of 3.45 sqm should be provided per 4-

               seater and a clear width of 750 mm from tables.

               A clear width of 1 m between wall and the table
               should be provided.

               A minimum  width  of 1.5  m  should be provided

               between two rectangular tables and 1.3 m between

               circular tables.


                                                                    Fig 61. Minimum spaces required in dining area
               Kitchen:

               Food provided in the hub includes only vegetarian

               menu,  thus,  provision  of  one  preparation  space,

               cooking area and service area.
               Preparation  area  includes  area  for  rinsing

               vegetables.

                                                                    Fig 62. Kitchen layout for 60-100 places


               Utility:

               Utensil/equipment rack for drying, a large enough
               wash basin for washing should be provided.



               Storage:


               A minimum of 10 sqm for dry storage and cold
               storage  each.  Refrigerators  can  be  used  to  store

               edible  products.  A  minimum  of  0.5x1.5  m  of

               refrigerator can be provided for per 100 meals.      Fig 63. Function scheme        Fig 64. Cafe Layout